Review



proteinchip cm10 weak cation exchanger array chip  (Bio-Rad)


Bioz Verified Symbol Bio-Rad is a verified supplier  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 93

    Structured Review

    Bio-Rad proteinchip cm10 weak cation exchanger array chip
    Proteinchip Cm10 Weak Cation Exchanger Array Chip, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 91 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/ProteinChip+CM10+Arrays/pm26011147-79-9-15
    Average 93 stars, based on 91 article reviews
    proteinchip cm10 weak cation exchanger array chip - by Bioz Stars, 2026-09
    93/100 stars

    Images

    Related Articles

    Binding Assay:

    Article Title: A Fragment of the LG3 Peptide of Endorepellin Is Present in the Urine of Physically Active Mining Workers: A Potential Marker of Physical Activity
    Article Snippet: The protein concentration of each urinary protein sample was determined in triplicate by bicinchoninic acid (BCA) protein assay (Pierce, Rockford, IL, USA) as per the manufacturer's instructions and adjusted to 0.42 mg/mL in binding buffer (10 mM sodium acetate (NaAc), pH 4.5). .. CM10 (weak cation exchange) ProteinChip® arrays (Bio-Rad, Hercules, CA, USA) were then pre-equilibrated twice with 50-μl of binding buffer using a ProteinChip Cassette – Compatible Bioprocessor® (Cat # C50-30011) (BioRad) and placed on a plate shaker for 5 min. Triplicate 35 μL sub-samples of urinary protein and a single QC replicate sample were applied to the surface of the CM10 arrays in a semi-randomised fashion to ensure that no replicate samples occupied a second spot on individual arrays. ..

    Article Title: Search for Breast Cancer Biomarkers in Fractionated Serum Samples by Protein Profiling With SELDI‐TOF MS
    Article Snippet: First, we tested the Immobilized Metal Affinity Capture (IMAC30) array (Bio‐Rad Labs) charged with copper sulfate (Merck, Darmstadt, Germany) with a binding buffer containing 0.01 M phosphate‐buffered saline pH 7.4 (Sigma, St Louis, MO) with 0.5M sodium chloride (Merck). .. Furthermore, we tested the weak cation exchange (CM10) array (Bio‐Rad Labs) with a binding buffer containing 100 mM sodium acetate pH 4 (Sigma). .. Finally, we tested the strong anion exchange (Q10) array (Bio‐Rad Labs) with a binding buffer containing 20 mM Tris–HCl pH 9 (Sigma).

    other:

    Article Title: Investigation of serum protein profiles in scrapie infected sheep by means of SELDI-TOF-MS and multivariate data analysis
    Article Snippet: A Weak cation exchange array (ProteinChip® CM10 Array, Bio-Rad) in combination with high stringency buffer, 50 mM HEPES pH 7.0 as binding and washing buffer was used to analyse the flow through (FT) fraction in this work.

    Centrifugation:

    Article Title: Excess Salt Increases Infarct Size Produced by Photothrombotic Distal Middle Cerebral Artery Occlusion in Spontaneously Hypertensive Rats
    Article Snippet: .. After centrifugation (14,000X g, 4°C, 20 min), supernatant was used for albumin and hemoglobin assays by using weak cation-exchange (CM10) ProteinChip Arrays (BIO-RAD Laboratories Inc., Hercules, CA, USA). ..

    Cell Culture:

    Article Title: The secretome of myocardial telocytes modulates the activity of cardiac stem cells
    Article Snippet: The proteins were separated and the data were analysed using specific software: Agilent 2100 Expert from Agilent Technology. .. The cell culture supernatants from mouse TCs and BALBc/3T3 cells were analysed in triplicate on a weak cation-exchange (CM10) ProteinChip array (Bio-Rad Laboratories, Hercules, CA, USA). ..



    Similar Products

    93
    Bio-Rad proteinchip cm10 weak cation exchanger array chip
    Proteinchip Cm10 Weak Cation Exchanger Array Chip, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/ProteinChip+CM10+Arrays/pm26011147-79-9-15
    Average 93 stars, based on 1 article reviews
    proteinchip cm10 weak cation exchanger array chip - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    93
    Bio-Rad weak cation exchanger array
    Weak Cation Exchanger Array, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/ProteinChip+CM10+Arrays/pm26426938-59-1-7
    Average 93 stars, based on 1 article reviews
    weak cation exchanger array - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    93
    Bio-Rad weak cation exchange cm10 proteinchip arrays
    Weak Cation Exchange Cm10 Proteinchip Arrays, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/ProteinChip+CM10+Arrays/pmc04016244-77-17-22
    Average 93 stars, based on 1 article reviews
    weak cation exchange cm10 proteinchip arrays - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    93
    Bio-Rad weak cation exchanger
    Weak Cation Exchanger, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/ProteinChip+CM10+Arrays/pm23289400-82-19-26
    Average 93 stars, based on 1 article reviews
    weak cation exchanger - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    93
    Bio-Rad weak cation exchange proteinchip cm10 arrays
    L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on <t>CM10</t> array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).
    Weak Cation Exchange Proteinchip Cm10 Arrays, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/ProteinChip+CM10+Arrays/pmc03317844-132-0-5
    Average 93 stars, based on 1 article reviews
    weak cation exchange proteinchip cm10 arrays - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    90
    Bio-Rad weak cation-exchange (cm10) proteinchip array
    L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on <t>CM10</t> array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).
    Weak Cation Exchange (Cm10) Proteinchip Array, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/ProteinChip+Q10+Arrays/pm19444605-61-21-26
    Average 90 stars, based on 1 article reviews
    weak cation-exchange (cm10) proteinchip array - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    93
    Bio-Rad weak cation exchange cm10 8 spot proteinchip arrays
    L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on <t>CM10</t> array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).
    Weak Cation Exchange Cm10 8 Spot Proteinchip Arrays, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/ProteinChip+CM10+Arrays/pm19393287-52-4-13
    Average 93 stars, based on 1 article reviews
    weak cation exchange cm10 8 spot proteinchip arrays - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    93
    Bio-Rad weak cation exchanger cm10 proteinchip arrays
    L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on <t>CM10</t> array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).
    Weak Cation Exchanger Cm10 Proteinchip Arrays, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/ProteinChip+CM10+Arrays/pm19322781-30-0-5
    Average 93 stars, based on 1 article reviews
    weak cation exchanger cm10 proteinchip arrays - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    90
    Ciphergen inc cm10 proteinchip® arrays (weak cation exchange arrays)
    L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on <t>CM10</t> array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).
    Cm10 Proteinchip® Arrays (Weak Cation Exchange Arrays), supplied by Ciphergen inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/weak+cation-exchange+(cm10)+proteinchip+array/wcx+2/pm18339181-186-14-21
    Average 90 stars, based on 1 article reviews
    cm10 proteinchip® arrays (weak cation exchange arrays) - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    Image Search Results


    L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on CM10 array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).

    Journal: Proteome Science

    Article Title: S100A10 protein expression is associated with oxaliplatin sensitivity in human colorectal cancer cells

    doi: 10.1186/1477-5956-9-76

    Figure Lengend Snippet: L-OHP sensitivity and candidate peak selection . (A) Protein expression profiles of each cell line on CM10 array at pH 4.5. The candidate peak is enclosed by the rectangle. (B) Peak intensity of the 11.1 kDa protein in 11 CRC cell lines strongly correlates with L-OHP sensitivity. The peak intensity and IC 50 value of each cell line are plotted as means ± S.D. (peak intensity, n = 3; IC 50 , n = 3 or 4).

    Article Snippet: Weak cation-exchange ProteinChip CM10 arrays (Bio-Rad Laboratories, Hercules, CA, USA) were used for protein profiling.

    Techniques: Selection, Expressing

    Characterization of the 11.1 kDa protein . (A) Estimation of pI of the 11.1 kDa protein. The affinity of the 11.1 kDa protein (indicated by the arrow) to a CM10 array changed with a pH range of 3.0-10.0. (B) Estimation of experimental molecular mass of the 11.1 kDa protein (indicated by the arrow). Bovine insulin (5733.5 Da) and equine cytochrome C (12361.0 Da) were calibrants for internal calibration.

    Journal: Proteome Science

    Article Title: S100A10 protein expression is associated with oxaliplatin sensitivity in human colorectal cancer cells

    doi: 10.1186/1477-5956-9-76

    Figure Lengend Snippet: Characterization of the 11.1 kDa protein . (A) Estimation of pI of the 11.1 kDa protein. The affinity of the 11.1 kDa protein (indicated by the arrow) to a CM10 array changed with a pH range of 3.0-10.0. (B) Estimation of experimental molecular mass of the 11.1 kDa protein (indicated by the arrow). Bovine insulin (5733.5 Da) and equine cytochrome C (12361.0 Da) were calibrants for internal calibration.

    Article Snippet: Weak cation-exchange ProteinChip CM10 arrays (Bio-Rad Laboratories, Hercules, CA, USA) were used for protein profiling.

    Techniques: